Certified spec comparison

ACIQ 18,000 BTU Wall-Mount vs MRCOOL DIY 18,000 BTU Wall-Mount

ACIQ ACIQ-18ZPL-HP230C vs MRCOOL DIYHH-18-HP-C-230D25-O

These two products come from different brands and share the same rounded certified heating-capacity class.

Every figure below is read from a certification record, not from a manufacturer marketing sheet. Where a registry publishes nothing, the row says so.

Why compare these models?

Both are 18k BTU-class heat pumps. Here is where they differ.

Certified field comparison

Field
ACIQ logoACIQ 18,000 BTU Wall-MountModel #: ACIQ-18ZPL-HP230C / ACIQ-18W-HH-MD
MRCOOL logoMRCOOL DIY 18,000 BTU Wall-MountModel #: DIYHH-18-HP-C-230D25-O / DIY-18-HP-WMAH-230D25-O
BrandACIQMRCOOL
Outdoor modelACIQ-18ZPL-HP230CDIYHH-18-HP-C-230D25-O
Heating capacity at 47F18,000 BTU/h18,000 BTU/h
Heating capacity at 17F18,000 BTU/h15,200 BTU/h
Heating capacity at 5F18,000 BTU/h18,000 BTU/h
SEER221.421.2
HSPF21111
Voltage208/230V208/230V
Certified flags
ENERGY STAR-certifiedccASHP-listed
ENERGY STAR-certifiedccASHP-listed
Compare sellers

ACIQ 18,000 BTU Wall-Mount

Compare sellers

MRCOOL DIY 18,000 BTU Wall-Mount

Check model number DIYHH-18-HP-C-230D25-O / DIY-18-HP-WMAH-230D25-O at your preferred retailer.

All values come from official certification records; “not supplied” means the source does not publish that value. Open either model page for source links and retrieval dates.

Cold-weather output: what each system still delivers when it gets cold

A heat pump's headline capacity is measured at 47°F. What matters in January is how much of that output survives at 17°F and 5°F. The cold-climate specification exists because two systems with the same 47°F rating can behave very differently at design temperature.

Certified heating outputACIQ ACIQ-18ZPL-HP230CMRCOOL DIYHH-18-HP-C-230D25-O
At 47°F18,000 BTU/h18,000 BTU/h
At 17°F18,000 BTU/h100% of its 47°F output15,200 BTU/h84% of its 47°F output
At 5°F18,000 BTU/h100% of its 47°F output18,000 BTU/h100% of its 47°F output
Cold-climate listedYes, on the NEEP cold-climate listYes, on the NEEP cold-climate list

ACIQ ACIQ-18ZPL-HP230C holds 100% of its 47°F output at 5°F. That is more than the 82% average across the 125 certified models in the same size class.

MRCOOL DIYHH-18-HP-C-230D25-O holds 100% of its 47°F output at 5°F. That is more than the 82% average across the 125 certified models in the same size class.

Output figures come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset; cold-climate listing comes from the NEEP cold-climate air-source heat pump product list. Retention percentages are calculated from those two published outputs.

Efficiency, and what each rating actually measures

SEER2

Measures cooling efficiency over a season.

ACIQ ACIQ-18ZPL-HP230C: 21.4. MRCOOL DIYHH-18-HP-C-230D25-O: 21.2. ACIQ ACIQ-18ZPL-HP230C is certified 0.2 points higher.

EER2

Measures cooling efficiency at one hot design condition.

ACIQ ACIQ-18ZPL-HP230C: 12.5. MRCOOL DIYHH-18-HP-C-230D25-O: 12.5. The two are certified at the same figure.

HSPF2

Measures heating efficiency over a season.

ACIQ ACIQ-18ZPL-HP230C: 11. MRCOOL DIYHH-18-HP-C-230D25-O: 11. The two are certified at the same figure.

ACIQ ACIQ-18ZPL-HP230C matches the 21.4 SEER2 average of the 125 certified models in its size class, and sits above the 10.2 HSPF2 average of the 125 certified models in its size class.

MRCOOL DIYHH-18-HP-C-230D25-O sits below the 21.4 SEER2 average of the 125 certified models in its size class, and sits above the 10.2 HSPF2 average of the 125 certified models in its size class.

SEER2, EER2, and HSPF2 come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset. Size-class averages are calculated across every certified model in this catalog rounded to the same capacity class.

Electrical and installation requirements

These decide whether a system is workable in a given house before efficiency matters at all. A model that needs a service you do not have is not a candidate.

RequirementACIQ ACIQ-18ZPL-HP230CMRCOOL DIYHH-18-HP-C-230D25-O
Electrical service208/230V208/230V
Minimum circuit ampacityNot published in the certification records19 A
Maximum breaker or fuseNot published in the certification records25 A
Line set length range98.4 ftNot published in the certification records

Not published for either model: pre-charged line set, homeowner-install product line. Those figures live in the manufacturer's installation manual, which is the document to ask for.

Electrical values are carried through from the certification records where the registries publish them. Confirm the final circuit requirement with a licensed electrician against the installation manual for the exact unit you buy.

Where these numbers come from

Three public registries stand behind this page. Each one answers a different question, and none of them is a review site.

Certification statusACIQ ACIQ-18ZPL-HP230CMRCOOL DIYHH-18-HP-C-230D25-O
AHRI reference number216032336216032551
ENERGY STARCertifiedCertified
NEEP cold-climate listListedListed

Records retrieved 2026-08-09. An AHRI certificate covers one outdoor unit paired with one indoor unit; a different indoor unit means a different certificate and different numbers.

What this comparison cannot tell you

Certified data settles output, efficiency, and cold-weather behaviour. It does not settle what a system costs to install in your house, how long the parts warranty runs, whether a local contractor will service the brand, or whether the unit fits the wall you had in mind. Those answers come from a quote and from the installation manual, not from a registry.

Capacity is a starting point, not a sizing decision. Two rooms with the same square footage can need different equipment once insulation, glazing, ceiling height, and climate zone are counted. Use a room-by-room load calculation before you buy either of these systems.

Check your room size