ACIQ logo9,800 BTU heat pump

ACIQ 9,800 BTU Ceiling Cassette

Model #: ACIQ-09ZPL-HP230B / ACIQ-09CC-HH-MB

Every spec on this page comes from an official certification record or a cited manufacturer document. The source is linked next to each value.

ACIQACIQMini-split heat pump
Compare sellers

Where to buy

Check model number ACIQ-09ZPL-HP230B / ACIQ-09CC-HH-MB at your preferred retailer.

We may earn a commission when you buy through seller links on this site. Learn more.

ACIQ ACIQ-09ZPL-HP230B outdoor mini-split unit

Photo of this model. Image details

Decision guide

At a glance

What the published numbers mean before you compare every spec.

Cold-weather output

At 5°F, certified output is 10,000 BTU/h — 102% of its 47°F rating.

ENERGY STAR ↗

DIY status not confirmed

The cited fields do not confirm a pre-charged line set or DIY-line designation for this model.

Electrical details missing

Voltage is not published in the sources we cite, so confirm it before choosing equipment.

Heating efficiency in its size class

HSPF2 10.3 is below the 10.4 average among 80 models in the same rounded capacity class.

ENERGY STAR ↗

Good fit if…

Your room is near 400–450 sq. ft. under the ENERGY STAR starting-point assumptions, and a load calculation agrees.

Think twice if…

You have not confirmed the voltage, room load, and installation requirements for this exact model.

Room guidance is a screening estimate for standard conditions. Check your room inputs; use Manual J for final sizing.

Certified spec table

Outdoor model numberACIQ-09ZPL-HP230BSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
Indoor model numberACIQ-09CC-HH-MBSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
AHRI reference number207825535Source: ENERGY STAR Mini-Split Heat Pumps dataset ·
SeriesACIQSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
Heating capacity at 47F9,800 BTU/hSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
Heating capacity at 17F9,000 BTU/hSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
Heating capacity at 5F10,000 BTU/hSource: ENERGY STAR Mini-Split Heat Pumps dataset ·
SEER220.5Source: ENERGY STAR Mini-Split Heat Pumps dataset ·
EER213Source: ENERGY STAR Mini-Split Heat Pumps dataset ·
HSPF210.3Source: ENERGY STAR Mini-Split Heat Pumps dataset ·

Values marked ENERGY STAR come from the certification dataset; values marked Manufacturer spec come from the linked product documents.

Specs not published for this model

The sources we cite do not publish these values for this model, so we leave them blank rather than guess.

VoltageMinimum circuit ampacityMaximum breaker / fuseLine set length rangePre-charged line setBrand DIY line

Check the fit for your room

Room-size guidance is a starting point, not a load calculation. Confirm sizing and installation requirements with a qualified contractor.

Check your room size