Room-size starting point
24,000 BTU is closest to ENERGY STAR’s 1400–1500 sq. ft. room-size row.
ENERGY STAR sizing chart ↗AHRI reference 215742359
Check model number SC-27Z-HH-M4B at your preferred retailer.

Photo of this model. Image details
What the published numbers mean before you compare every spec.
24,000 BTU is closest to ENERGY STAR’s 1400–1500 sq. ft. room-size row.
ENERGY STAR sizing chart ↗At 5°F, certified output is 21,600 BTU/h — 90% of its 47°F rating.
ENERGY STAR ↗The cited fields do not confirm a pre-charged line set or DIY-line designation for this model.
Voltage is not published in the sources we cite, so confirm it before choosing equipment.
HSPF2 10 is below the 10.0 average among 70 models in the same rounded capacity class.
ENERGY STAR ↗Your room is near 1400–1500 sq. ft. under the ENERGY STAR starting-point assumptions, and a load calculation agrees.
You have not confirmed the voltage, room load, and installation requirements for this exact model.
Room guidance is a screening estimate for standard conditions. Check your room inputs; use Manual J for final sizing.
| Outdoor model number | SC-27Z-HH-M4B |
|---|---|
| AHRI reference number | 215742359 |
| Series | Extreme Heat |
| Heating capacity at 47F | 24,000 BTU/h |
| Heating capacity at 17F | 23,600 BTU/h |
| Heating capacity at 5F | 21,600 BTU/h |
| SEER2 | 21 |
| EER2 | 12.5 |
| HSPF2 | 10 |
Values marked ENERGY STAR come from the certification dataset; values marked Manufacturer spec come from the linked product documents.
DIYCOOL SC-27Z-HH-M4B appears in the certification records under 2 separate certificate numbers. The equipment is the same; the tested pairing and the resulting ratings differ. This page carries them all.
| AHRI reference | Indoor unit | Heating at 47°F | Heating at 5°F | SEER2 | HSPF2 |
|---|---|---|---|---|---|
| 215742359 | Not supplied | 24,000 BTU/h | 21,600 BTU/h | 21 | 10 |
| 215742358 | Not supplied | 24,000 BTU/h | 21,600 BTU/h | 21 | 10 |
Every row comes from the same certification record set, retrieved 2026-08-09. Ask the seller which certificate number the unit you are quoted matches.
The sources we cite do not publish these values for this model, so we leave them blank rather than guess.
Room-size guidance is a starting point, not a load calculation. Confirm sizing and installation requirements with a qualified contractor.