Multi-zone sizing needs a load calculation
48,000 BTU is sized across zones. Each zone needs its own load calculation.
ACCA Manual J ↗AHRI reference 217291701
Check model number MULTI6-48HP230C-O at your preferred retailer.

Photo of this model. Image details
What the published numbers mean before you compare every spec.
48,000 BTU is sized across zones. Each zone needs its own load calculation.
ACCA Manual J ↗At 5°F, certified output is 36,000 BTU/h — 75% of its 47°F rating.
ENERGY STAR ↗The cited fields do not confirm a pre-charged line set or DIY-line designation for this model.
208/230V equipment; confirm the dedicated circuit and disconnect requirements with an electrician.
Manufacturer spec ↗HSPF2 10.3 is above the 10.0 average among 46 models in the same rounded capacity class.
ENERGY STAR ↗A room-by-room load calculation supports this outdoor system across the planned zones.
You have not calculated each zone’s load or accounted for 208/230V equipment.
Multi-zone systems need room-by-room load calculations and zone planning; use Manual J for final sizing.
| Outdoor model number | MULTI6-48HP230C-O |
|---|---|
| AHRI reference number | 217291701 |
| Series | MULTI |
| Heating capacity at 47F | 48,000 BTU/h |
| Heating capacity at 17F | 40,000 BTU/h |
| Heating capacity at 5F | 36,000 BTU/h |
| SEER2 | 24 |
| EER2 | 12.5 |
| HSPF2 | 10.3 |
| Voltage | 208/230V |
| Minimum circuit ampacity | 34 A |
| Maximum breaker / fuse | 40 A |
Values marked ENERGY STAR come from the certification dataset; values marked Manufacturer spec come from the linked product documents.
MRCOOL MULTI6-48HP230C-O appears in the certification records under 3 separate certificate numbers. The equipment is the same; the tested pairing and the resulting ratings differ. This page carries them all.
| AHRI reference | Indoor unit | Heating at 47°F | Heating at 5°F | SEER2 | HSPF2 |
|---|---|---|---|---|---|
| 217291701 | Not supplied | 48,000 BTU/h | 36,000 BTU/h | 24 | 10.3 |
| 217291702 | Not supplied | 47,000 BTU/h | 38,000 BTU/h | 20.4 | 10.6 |
| 217291703 | Not supplied | 47,500 BTU/h | 37,000 BTU/h | 22.2 | 10.45 |
Every row comes from the same certification record set, retrieved 2026-08-09. Ask the seller which certificate number the unit you are quoted matches.
The sources we cite do not publish these values for this model, so we leave them blank rather than guess.
Room-size guidance is a starting point, not a load calculation. Confirm sizing and installation requirements with a qualified contractor.
Check your room size